Radar Level Meter
Working Mob:(86)18930843859
Working Skype: shcixi-xiong
Guided wave radar material level gauge
types
|
CX-RLM-071
|
CX-RLM-072
|
CX-RLM-073
|
Application
|
Liquid, solid granules
|
Liquid, solid granules
|
Liquid
|
Measuring range
|
30 meters
|
6 meters
|
6 meters
|
Process connection
|
Screw, flange
|
Screw, flange
|
Screw, flange
|
Process temperature
|
-40-250℃
|
-40-250℃
|
-40-250℃
|
Process pressure
|
-1.0-40bar
|
-1.0-40bar
|
-1.0-40bar
|
Precision
|
±1mm
|
±1mm
|
±1mm
|
Frequency range
|
100MHZ-1.8GHZ
|
100MHZ-1.8GHZ
|
100MHZ-1.8GHZ
|
Anti-explosion/safety
grade
|
EXiaIICT6/IP68
|
EXiaIICT6/IP68
|
EXiaIICT6/IP68
|
Signal output
|
4…20mA/HART(two phases)
|
4…20mA/HART
(two phases)
|
4…20mA/HART
(two phases)
|
Intelligent Radar level meter
Types
|
CX-RLM-81
|
CX-RLM-082
|
CX-RLM-083
|
Application
|
Process condition is simple, corrosive liquids, slurries and solids
For example:
Water tank
Acid and alkali tanks
Slurry tanks
Solid granules
Small petrol tanks
|
Storing corrosive liquids, slurries and solids
For example:
Water tank
Acid and alkali tanks
Slurry tanks
Solid granules
Small petrol tanks
|
Suitable for all kinds of storing tanks or process measuring environment, liquids, slurries and solids.
For example:
Crude oil, light oil tank
Coal and powder coal bunkers
Volatile liquid tank
Charcoal level
Slurry tank
Solid granules
|
Measuring range
|
20 meters
|
20 meters
|
35 meters
|
Process connection
|
Screw
|
Flange
|
Flange
|
Process temperature
|
-40-130℃
|
-40-150℃
|
-40-250℃
|
Process pressure
|
-1.0-3bar
|
-1.0-20bar
|
-1.0-40bar
|
Repeatability
|
± 3mm
|
± 3mm
|
± 3mm
|
Precision
|
< 0.1%
|
< 0.1%
|
< 0.1%
|
Frequency range
|
6.8GHz
|
6.8GHz
|
6.8GHz
|
Anti-explosion/safety grade
|
EXiaIICT6/IP68
|
EXiaIICT6/IP68
|
EXiaIICT6/IP68
|
Signal output
|
4…20mA/HART
(two phases)
|
4…20mA/HART
(two phases)
|
4…20mA/HART
(two phases)
|
26GHz Pulse Radar Level Meter
The guided wave radar level instrument, adopted 26GHz as transmitting frequency, which make this series have specialties as
below:
1. jamming, hence high accuracy and reliable.
2. Small antenna size, easy to mount and easy to equip extra dust protection
3. Small blind zone, good accuracy even for small.
4. Shorter wave-length, suitable for the measurement of powder, grain and etc.
5. The guided wave radar level instrument, with pulses as its working tool and extremely low emission power, can be mounted
on various metal or nonmetal vessels, harmless towards the environment and human beings.
Equipped with advanced microprocessor and unique Echo Discovery echo processing
technology, the radar level instrument can be used under various hazardous process onditions
General Parameters
Product
model
|
805
|
806
|
807
|
808
|
809
|
Process
connection
|
ThreadG1½A
|
ThreadG1½A
|
ThreadG1½A
|
ThreadG1½A
| |
Thread1½NPT
|
Thread1½NPT
|
Thread1½NPT
| |||
Flange
|
Flange
|
Flange
|
Flange
| ||
Material
|
PTFE
|
Stainless
steel316L/
PTFE
|
PTFE
|
Stainless
steel316L
/PTFE
|
Stainless
steel316L
/PTFE
|
Housing
|
Plastic PBT-FR Aluminium,Stainless
|
Steel 316L
| |
Seal ring between housing and housing cover
|
Silicone
|
View Point window on housing
|
Polycarbonate
|
Ground terminal
|
Stainless Steel
|
Characteristic parameter
Blind spot
|
end of antenna
|
Max. measurement distance
| |
CX-RLM-805
|
10m(liquid)
|
CX-RLM-806
|
30m(liquid)
|
CX-RLM-807
|
20m(liquid)
|
CX-RLM-807
|
80m(solid)
|
CX-RLM-809
|
30m(solid)
|
Microwave frequency
|
26GHz
|
Measurement interval
|
about 1 sec. (depend on parameter settings)
|
Adjustment time
|
about 1 sec. (depend on parameter settings)
|
Resolution on display
|
1mm
|
Accuracy
|
see the diagram below
|
Temperature for storage/transport
|
-40-+80C
|
Process temperature(probe)
| |
CX-RLM-805
|
-40-+130C
|
CX-RLM-806
|
-40-+200C
|
CX-RLM-807
|
-40-+150C
|
CX-RLM-807
|
-40-+200C
|
CX-RLM-809
|
-40-+60C
|
Relative humidity
|
<95%
|
Pressure
|
Max.4MPa
|
Vibration proof
|
mechanical vibration 10m/s2,(10~150)Hz
|
Details
Package
Factory
Installation
Certificate
Transportation